TEL:0086-311-88862036
Iimayl:info@biloowtel.com
TEL:
0086-311-88862036

Usha kulul ee Telescopic

Warshadaha qaybinta tamarta korontada, ul kulul waa tiir dahaaran, oo inta badan laga sameeyo fiberglass, oo ay adeegsadaan shaqaalaha tamarta korantada marka ay ku hawlan yihiin khadka tooska ah ee ka shaqeynaya xadhkaha korantada ee tamarta sare leh, si ay uga ilaaliyaan shoogga korontada. Iyada oo ku xidhan aaladda ku dheggan dhamaadka usha kulul, fur oo xidh furayaasha, beddel fiyuusyada, dul saar fiilooyinka gacmaha dahaadhka ah, oo samee hawlo kale oo kala duwan adigoon shaqaalaha u soo bandhigin khatar weyn oo koronto ah



PDF soo dejiso
Faahfaahin
Tags
 
Tilmaamid

 

Qaabka

La dheereeyey

dhererka (m)

Dhererka dib loo celiyay (m)

Dhexroorka saldhiga (mm)

Qaybaha

Miisaanka

(kg)

RHS-300

3

1.27

37

3

1.92

RHS-400

4

1.65

37

3

2.24

RHS-450

4.5

1.76

37

3

2.32

RHS-500

5

1.95

37

3

2.4

RHS-600

6

2.25

37

3

2.72

RHS-400-4

4

1.35

43.5

4

3.12

RHS-500-4

5

1.65

43.5

4

3.26

RHS-600-4

6

1.85

43.5

4

3.5

RHS-700

7

2.1

43.5

4

3.74

RHS-750

7.5

2.2

43.5

4

4

RHS-500-5

5

1.45

50

5

3.2

RHS-600-5

6

1.65

50

5

3.65

RHS-700-5

7

1.85

50

5

3.75

RHS-750-5

7.5

1.95

50

5

3.95

RHS-800

8

2.07

50

5

4.1

RHS-900

9

2.2

50

5

4.3

RHS-1000

10

2.45

50

5

4.4

 

 
Bandhiga Alaabta

 

  • Read More About hot stick
  • Read More About hot stick
  • Read More About telescopic hot stick
  • Read More About high voltage shotgun stick

 

 
Astaamaha

 

  • 1. Dahaarka: Ulaha kulul ayaa inta badan looga baahan yahay inay lahaadaan tilmaamayaasha sida ilaalinta, dahaadhka, iyo dulqaadka cadaadiska si loo hubiyo badbaadada shaqaalaha inta lagu jiro hawlgalka.
  • 2. Naqshad dib loo celin karo: Qaar ka mid ah ulaha kulul waxay qaataan naqshad dib loo celin karo, kaas oo dib loo celin karo oo la dhigi karo dherer kasta iyadoo loo eegayo booska la isticmaalo, taas oo sahlaysa in la qaado lana isticmaalo.
  • 3. Naqshadaynta Interface: Qaar ka mid ah ulaha kulul waxay qaataan nashqad interface ah, oo leh isdhexgal wareeg ah oo ku yaal qaybaha, kuwaas oo lagu dhejin karo qaybo si fudud loo qaado.
  • 4. Tayada iyo kalsoonida: Sida qalabka samatabbixinta xirfadlaha ah, tayada Hot Stick waa mid ka mid ah sifooyinka muhiimka ah. Nashqaddeeda casriga ah iyo wax-soo-saarkeeda waxay hubisaa inay si deggan oo kalsooni leh ugu shaqayn karto deegaanno adag oo khatar ah.
Read More About hot stick electrical

 

Using a Telescopic Hot Stick for Energized Equipment Handling and Safe Distancing


Working with energized electrical systems requires strict adherence to safety standards, and the Telescopic Hot Stick is a fundamental tool that enables operators to maintain safe distancing while handling energized equipment. Its primary purpose is to protect workers from electrical hazards by providing an extended, insulated reach. Whether used on overhead lines, transformers, switchgear, or distribution networks, the Telescopic Hot Stick ensures workers can control, test, or manipulate components without direct exposure to high-voltage circuits.


One of the most common applications is performing switching operations on energized overhead lines. The adjustable telescopic length allows workers to remain at a safe distance while opening or closing switches, operating cutouts, and installing or removing line accessories. By maintaining proper electrical clearance, the risk of arc flash or accidental contact is significantly reduced. The lightweight fiberglass structure also minimizes fatigue, allowing operators to perform extended tasks more efficiently.


The Telescopic Hot Stick is equally important when handling energized equipment during maintenance activities. Workers may use it to reposition jumpers, tighten connectors, remove obstructions, or apply grounding devices in certain configurations. In situations where equipment failure or storm damage creates unpredictable hazards, the hot stick acts as a first-contact safety tool, enabling operators to secure the area before conducting repairs.


Another key function is supporting voltage detection and testing. With the appropriate attachments, technicians can attach voltage detectors, phasing testers, or fault indicators to the end of the stick. This allows them to verify power presence, check circuit continuity, and confirm operational conditions before proceeding with repair work. Because testing is often performed on live systems, the insulated stick ensures that measurements can be taken without placing workers at risk.


Maintaining safe distancing is not only a best practice but a regulatory requirement in most utility environments. The Telescopic Hot Stick helps workers meet clearance guidelines defined by national electrical safety standards. Its adjustable design ensures crews can choose the correct length for specific equipment height, voltage level, or worksite configuration. The ability to extend and retract the stick quickly improves overall workflow efficiency.
Proper training and tool maintenance are also essential. Before each use, workers inspect the stick’s surface for moisture, contamination, or structural damage. Routine cleaning and dielectric testing ensure long-term reliability. When used correctly, the Telescopic Hot Stick becomes a dependable safety barrier that allows field crews to perform energized operations confidently.


In conclusion, the Telescopic Hot Stick is indispensable for energized equipment handling and safe distancing practices. It enhances worker protection, supports efficient power system operations, and ensures compliance with electrical safety standards across all high-voltage environments.

 

Telescopic Hot Stick Applications in Substation Switching and High-Voltage Inspections


The Telescopic Hot Stick is one of the most important tools used by electrical utility crews, especially during substation switching and high-voltage inspections. Its insulated fiberglass construction allows operators to perform critical tasks without directly touching energized components, providing maximum protection against electrical shock, arc flash, and accidental contact. Because substations handle extremely high voltage levels, ranging from distribution voltages to hundreds of kilovolts, maintaining a safe working distance is essential. The telescopic design enables workers to adjust the length of the stick according to the task, ensuring both flexibility and safety.


In substation environments, the Telescopic Hot Stick is essential for switching operations such as opening and closing disconnect switches, removing line fuses, engaging load break devices, and manipulating bushings or contacts. These operations frequently require precision and stability, particularly in high-voltage bays where equipment spacing is limited. Using a telescopic stick reduces the operator’s risk by creating a physical barrier between the worker and the energized apparatus. Its lightweight construction also ensures smooth handling, even during repetitive switching sequences.


During high-voltage inspections, the Telescopic Hot Stick enables technicians to safely check equipment conditions without shutting down power. Crews use the stick to test for voltage presence, measure conductor clearance, verify equipment integrity, and interact with devices such as testers, sensors, or audible indicators. Because inspections often occur while systems remain energized, the insulating properties of the stick are crucial in preventing unintended electrical conduction.


Regular substation maintenance tasks, including cleaning insulators, removing debris, and performing mechanical adjustments, also rely on the Telescopic Hot Stick. The adjustable length ensures workers can reach elevated components such as breakers, transformers, or overhead bus bars. Additionally, the telescopic sections lock securely into place, providing stability and preventing collapse during use.


Utility companies also establish strict operating procedures that require keeping Telescopic Hot Sticks readily accessible in substations. Technicians receive continuous training on correct handling, inspection routines, and maintenance techniques to ensure optimal tool performance. A well-maintained hot stick significantly reduces the risk of electrical accidents and is a mandatory component of any professional high-voltage safety program.
Overall, the Telescopic Hot Stick plays an indispensable role in substation switching and high-voltage inspections, allowing workers to carry out essential operations efficiently, safely, and in accordance with electrical industry standards.

 

qoriga toogashada danab sare

ul kulul

ul kulul koronto

qoriga qoriga

Usha kulul ee telescopic

Haddii aad xiisaynayso alaabtayada, waxaad dooran kartaa inaad macluumaadkaaga kaga tagto halkan, wax yarna waanu kula soo xidhiidhi doonaa.


logo
BlLo lmport & Éxport waxay ku takhasustay korantada iyo qalabka fiilooyinka iyo agabka tixgelinta, wax soo saarka Qur'aanka ee ugu muhiimsan waa rodder duct FRP, cable rollerscable winch, cable drum jack, cable jiid sharabaad, iwm.

Haddii aad xiisaynayso alaabtayada, waxaad dooran kartaa inaad macluumaadkaaga kaga tagto halkan, wax yarna waanu kula soo xidhiidhi doonaa.