TEL:0086-311-88862036
E-post: info@bilopowtel.com
TEL:
0086-311-88862036

Hege spanning tydlike koartsluting ierdingsets 

De tydlike ierdingsapparatuer is ûntworpen om arbeiders te beskermjen tsjin hege spanning elektryske skokken. Geskikt foar it ierd meitsjen fan apparatuer dy't útfalt of tydlik koartsluten is yn liedingen, om te foarkommen dat ûnferwachte stroom ynkomt en skea oan personiel en apparatuer feroarsaket.



PDF DOWNLOAD
Details
Tags
 
Yntrodusearje

 

  •  It bestiet benammen út ierdstokken, ierdkabels, ierdklemmen of ierdpen.
  • Yn 't algemien binne der trije manieren om de ierdingsapparatuer oan te sluten en op te hingjen.
  • Kombinaasjetype, tandemtype en ienfazetype.

 

 
Spesifikaasje

 

 Wy kinne dit produkt oanpasse neffens de easken.

Model

Ground

Cboppeste tried Grutte

Oanrikkemandearre

Lingte fan Cboppeste tried

Lingte fan

Grûnstok

Oantal fan

Grûnstok

BLDX-0.4KV

16mm²

3x1.5m+8m

0,5m

3 stangen/set

BLDX-10KV

25mm²

3x1,5m+10m

1.0m

3 stangen/set

BLDX-35KV

35mm²

3x1,5m+10m

1,5m

3 stangen/set

BLDX-110KV

35mm²

3x2m+12m

2.0m

3 stangen/set

BLDX-220KV

50mm²

3x2m+15m

3.0m

3 stangen/set

Opmerking: De grutte kin oanpast wurde neffens jo easken.

 

 

Takomst

 

  • De rubberen handgreep foeget antisliplinen en isolearre rok ta foar nofliker grip en feiliger gebrûk.
  • It lichem fan 'e grûnstangbuis is makke fan epoxyharsglêsfezelmateriaal, dat goede isolaasje en hege feiligens hat.
  • Goed útharde aluminium spuitgieten ierdklem, mei hege hurdens, sterke kompresjeresistinsje en duorsumens, en soarget foar langduorjend praktysk gebrûk foar jo.
  • Dûbeltonge ierdklem, makke fan heechweardige aluminium, stevich en duorsum. It klemgebiet hat slijtvaste yndrukking om de wriuwing te ferbetterjen.
  • Suvere koperen ierdingstried, makke fan mearstrengs sêfte kopertried, dy't poerbêste elektryske gelieding biedt. It is bedekt mei in fleksibele, hege-temperatuerbestindige transparante isolearjende beskermjende laach, dy't slijtage fan 'e ierdingstried tidens gebrûk foarkomt. De kopertried foldocht oan 'e easken foar wurgenstests, wêrtroch't de feiligens fan operators tidens operaasje garandearre wurdt.
  • Dûbelgat koperen lug, de ierdingsdraad is al krimpt mei koperen lugs, en de ierdingsdraad is ek bedekt mei in transparante isolearjende plestik buis, wat de feiligens fan 'e ierdingsdraad sterk ferbetteret.

 

Why High Voltage Temporary Short Circuit Earthing Sets Are Essential for Fault Prevention


High Voltage Temporary Short Circuit Earthing Sets are critical safety devices used to protect electrical workers and power systems during maintenance, inspection, and emergency operations. These grounding sets create a controlled short circuit path that safely diverts unexpected electrical energy away from workers, preventing accidental energization, induced voltages, and electrical faults that could result in severe injury or system damage. In high-voltage networks where operational risks are significant, earthing sets form a core component of fault prevention and system stability.


One of the primary reasons these earthing sets are essential is their ability to provide a low-resistance pathway for fault currents. When maintenance is performed on power lines, transformers, or switchgear, the electrical system must be isolated. However, isolation alone cannot guarantee complete safety. Residual charges, back-feed from interconnected circuits, or accidental re-energization can still occur. High Voltage Temporary Short Circuit Earthing Sets eliminate these risks by ensuring any unexpected current flows harmlessly to ground.


Another key factor is worker protection. High-voltage environments expose technicians to induced voltages created by nearby energized conductors. Without grounding, these induced voltages can reach dangerous levels. By applying temporary earthing, induced energy is neutralized, keeping electrical potential at safe levels and providing a secure environment for maintenance teams.


From a system reliability perspective, temporary short circuit earthing sets help prevent equipment damage during faults. If a line is mistakenly energized while workers are present, the grounding set forces the system into a short circuit condition that activates protective relays and circuit breakers. This rapid disconnection minimizes arc flash intensity and prevents catastrophic damage to electrical infrastructure.


These grounding sets also support industry compliance. Electrical safety regulations require proper bonding and grounding procedures before any work is conducted on de-energized lines. Using certified High Voltage Temporary Short Circuit Earthing Sets ensures adherence to safety standards and reduces liability for utility companies.


In summary, these earthing sets are indispensable for fault prevention because they protect workers, stabilize electrical systems, reduce equipment damage, and ensure regulatory compliance. Without them, high-voltage maintenance would be significantly more dangerous and less controlled.

 

Using High Voltage Temporary Short Circuit Earthing Sets for Overhead Line Earthing Operations


High Voltage Temporary Short Circuit Earthing Sets play a vital role in ensuring worker safety during overhead line earthing operations. When utility crews perform maintenance on transmission or distribution lines, they must create a safe work zone by attaching grounding clamps and conductors that provide a direct path for any unexpected electrical energy to flow to earth. This prevents hazardous voltages from remaining on the line and ensures complete protection against induced currents, lightning surges, and accidental re-energization.


Overhead line operations often involve long conductive spans that are exposed to environmental and electrical influences. Even when lines are disconnected, electromagnetic induction from nearby energized circuits can create dangerous voltages. Temporary earthing sets eliminate this risk by equalizing electrical potential and keeping the line effectively grounded throughout the operation.


The process begins with selecting the appropriate earthing set based on the voltage level, fault current capacity, and conductor size. The earthing set typically consists of insulated sticks, high-strength clamps, flexible copper cables, and an earth-end connector. Workers first attach the earth clamp to a designated grounding point, ensuring a solid connection to the substation grounding grid or an approved earthing rod. This step establishes the earth reference before any connection is made to the overhead line.


Next, workers use an insulated operating stick to install line clamps on each phase conductor. By connecting all phases together and tying them to ground, the High Voltage Temporary Short Circuit Earthing Set ensures the line is at zero potential. This configuration protects maintenance personnel from unexpected electrical surges and ensures that if the line is accidentally energized, the fault current will immediately trip upstream protection devices.
These earthing sets are also essential when performing work such as replacing insulators, installing hardware, inspecting conductors, or addressing storm-related damage. The grounding arrangement stabilizes the system and creates an electrically safe environment for all crew members working at height.


Regular training is necessary to ensure crews understand correct installation techniques. Proper cleaning, inspection, and testing of earthing equipment also guarantee consistently high performance. Damaged or contaminated grounding components can compromise safety, so routine checks are mandatory.


In conclusion, High Voltage Temporary Short Circuit Earthing Sets are indispensable for overhead line earthing operations. They protect workers from induced voltages, create a safe work zone, ensure rapid fault clearance, and enhance the reliability of high-voltage maintenance activities.

 

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.


Copyright © 2026 Shijiazhuang Bilo Ymport en Eksport Trading Co., Ltd. Alle rjochten foarbehâlden. Sitemap | Privacybelied
logo
BlLo import & eksport is spesjalisearre yn stroom- en kabelapparatuer en bou-ark. Us wichtichste produkten binne FRP-kanaalstangen, kabelrollen, kabellûklieren, kabeltrommelkrik, kabellûksokken, ensfh.
Copyright © 2026 Shijiazhuang Bilo Ymport en Eksport Trading Co., Ltd. Alle rjochten foarbehâlden. Sitemap | Privacybelied

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.