TEL:0086-311-88862036
I-imeyile:info@bilopowtel.com
TEL:
0086-311-88862036

ISeti zoMhlaba zeSetyhula eziMfutshane zeSekethe yeThutyana yoMbane oPhezulu 

Izixhobo zokumisa okwethutyana ziyilelwe ukuba zisetyenziswe ukukhusela abasebenzi kumoyiko wombane wamandla aphezulu. Ilungele ukwenza izixhobo ezingasebenziyo zombane okanye iintambo zethutyana ezijikelezayo zisekelwe, zithintela amandla angalindelekanga ukuba angene kwaye enze umonakalo kubasebenzi nakwizixhobo.



PDF Khuphela
Iinkcukacha
Iithegi
 
Yazisa

 

  •  Ubukhulu becala ibandakanya iiNtonga eziGround, iCable eGround, iGround Clamp okanye iPin yeGround.
  • Ngokubanzi, kukho iindlela ezintathu zokudibanisa kunye nokuxhoma izixhobo zokumisa.
  • Uhlobo lokudibanisa, uhlobo lwe-tandem kunye nohlobo lwesigaba esinye.

 

 
Inkcazo

 

 Sinokuyilungisa le mveliso ngokweemfuno.

Umzekelo

Ground

Cucingo olungaphezulu Ubungakanani

Kucetyiswa

Ubude beCucingo olungaphezulu

Ubude be

Intonga yomhlaba

Inani le

Intonga yomhlaba

BLI-DX-0.4KV

16mm²

3x1.5m+8m

0.5m

3 iintonga/iseti

BLI-DX-10KV

25mm²

3x1.5m+10m

1.0m

3 iintonga/iseti

BLDX-35KV

35mm²

3x1.5m+10m

1.5m

3 iintonga/iseti

BLDX-110KV

35mm²

3x2m+12m

2.0m

3 iintonga/iseti

BLDX-220KV

50mm²

3x2m+15m

3.0m

3 iintonga/iseti

Phawula: Ubungakanani bungenziwa ngokweemfuno zakho.

 

 

Ikamva

 

  • Umqheba werabha wongeza imigca engatyibilikiyo kunye nesiketi esigqunyiweyo ukuze ubambe ngokukhululeka kunye nokusetyenziswa okukhuselekileyo.
  • Umzimba wetyhubhu yomhlaba wenziwe ngezinto ze-epoxy resin zeglasi yefiber, ene-insulation elungileyo kunye nokhuseleko oluphezulu.
  • I-aluminiyam enyangelwe kakuhle yokuphosa isibambiso sokubeka umhlaba, enobunzima obuphezulu, ukuxhathisa okuqinileyo, kunye nokuqina, iqinisekisa ukusetyenziswa okusebenzayo ixesha elide kuwe.
  • Isibambiso esisezantsi solwimi oluphindwe kabini, esenziwe nge-aluminiyam ekumgangatho ophezulu, eyomeleleyo kwaye yomelele. Indawo ebambekayo ine-indent engagugiyo ukomeleza ukukhuhlana.
  • Ucingo olusulungekileyo lokumisa ubhedu, olwenziwe ngocingo oluthambileyo lwe-multi-strand, olunikezela ngombane ogqwesileyo. Igqutywe nge-flexible, high-temperature resistant transparent insulating protective layer, inqanda ukuguga kunye nokukrazula kocingo lokumisa ngexesha lokusetyenziswa. Ucingo lobhedu luhlangabezana neemfuno zokuvavanya ukukhathala, ukuqinisekisa ukhuseleko lwabaqhubi ngexesha lokusebenza.
  • I-double-hole copper lug, i-wire grounding isele ihlanjululwe ngeentsimbi zobhedu, kwaye ucingo lokumisa luphinde luhlanganiswe netyhubhu yeplastiki ye-insulating ecacileyo, iphucula kakhulu ukhuseleko locingo lokumisa.

 

Why High Voltage Temporary Short Circuit Earthing Sets Are Essential for Fault Prevention


High Voltage Temporary Short Circuit Earthing Sets are critical safety devices used to protect electrical workers and power systems during maintenance, inspection, and emergency operations. These grounding sets create a controlled short circuit path that safely diverts unexpected electrical energy away from workers, preventing accidental energization, induced voltages, and electrical faults that could result in severe injury or system damage. In high-voltage networks where operational risks are significant, earthing sets form a core component of fault prevention and system stability.


One of the primary reasons these earthing sets are essential is their ability to provide a low-resistance pathway for fault currents. When maintenance is performed on power lines, transformers, or switchgear, the electrical system must be isolated. However, isolation alone cannot guarantee complete safety. Residual charges, back-feed from interconnected circuits, or accidental re-energization can still occur. High Voltage Temporary Short Circuit Earthing Sets eliminate these risks by ensuring any unexpected current flows harmlessly to ground.


Another key factor is worker protection. High-voltage environments expose technicians to induced voltages created by nearby energized conductors. Without grounding, these induced voltages can reach dangerous levels. By applying temporary earthing, induced energy is neutralized, keeping electrical potential at safe levels and providing a secure environment for maintenance teams.


From a system reliability perspective, temporary short circuit earthing sets help prevent equipment damage during faults. If a line is mistakenly energized while workers are present, the grounding set forces the system into a short circuit condition that activates protective relays and circuit breakers. This rapid disconnection minimizes arc flash intensity and prevents catastrophic damage to electrical infrastructure.


These grounding sets also support industry compliance. Electrical safety regulations require proper bonding and grounding procedures before any work is conducted on de-energized lines. Using certified High Voltage Temporary Short Circuit Earthing Sets ensures adherence to safety standards and reduces liability for utility companies.


In summary, these earthing sets are indispensable for fault prevention because they protect workers, stabilize electrical systems, reduce equipment damage, and ensure regulatory compliance. Without them, high-voltage maintenance would be significantly more dangerous and less controlled.

 

Using High Voltage Temporary Short Circuit Earthing Sets for Overhead Line Earthing Operations


High Voltage Temporary Short Circuit Earthing Sets play a vital role in ensuring worker safety during overhead line earthing operations. When utility crews perform maintenance on transmission or distribution lines, they must create a safe work zone by attaching grounding clamps and conductors that provide a direct path for any unexpected electrical energy to flow to earth. This prevents hazardous voltages from remaining on the line and ensures complete protection against induced currents, lightning surges, and accidental re-energization.


Overhead line operations often involve long conductive spans that are exposed to environmental and electrical influences. Even when lines are disconnected, electromagnetic induction from nearby energized circuits can create dangerous voltages. Temporary earthing sets eliminate this risk by equalizing electrical potential and keeping the line effectively grounded throughout the operation.


The process begins with selecting the appropriate earthing set based on the voltage level, fault current capacity, and conductor size. The earthing set typically consists of insulated sticks, high-strength clamps, flexible copper cables, and an earth-end connector. Workers first attach the earth clamp to a designated grounding point, ensuring a solid connection to the substation grounding grid or an approved earthing rod. This step establishes the earth reference before any connection is made to the overhead line.


Next, workers use an insulated operating stick to install line clamps on each phase conductor. By connecting all phases together and tying them to ground, the High Voltage Temporary Short Circuit Earthing Set ensures the line is at zero potential. This configuration protects maintenance personnel from unexpected electrical surges and ensures that if the line is accidentally energized, the fault current will immediately trip upstream protection devices.
These earthing sets are also essential when performing work such as replacing insulators, installing hardware, inspecting conductors, or addressing storm-related damage. The grounding arrangement stabilizes the system and creates an electrically safe environment for all crew members working at height.


Regular training is necessary to ensure crews understand correct installation techniques. Proper cleaning, inspection, and testing of earthing equipment also guarantee consistently high performance. Damaged or contaminated grounding components can compromise safety, so routine checks are mandatory.


In conclusion, High Voltage Temporary Short Circuit Earthing Sets are indispensable for overhead line earthing operations. They protect workers from induced voltages, create a safe work zone, ensure rapid fault clearance, and enhance the reliability of high-voltage maintenance activities.

 

izixhobo zamandla okwakha

izixhobo zokwakha amandla

uluhlu lwezixhobo zamandla pdf

uluhlu lwezixhobo zamandla ngemifanekiso pdf

izixhobo zamandla ezisecaleni zoluhlu lwepdf

Ukuba unomdla kwiimveliso zethu, unokukhetha ukushiya ulwazi lwakho apha, kwaye siya kuqhagamshelana nawe kungekudala.


logo
I-BlLo lmport & Éxport ikhethekileyo kumandla kunye nezixhobo zentambo kunye nezixhobo zokuqwalasela, i-Qur eyona nto iphambili yeemveliso yi-FRP duct rodder, i-cable rollersable pulling winch, i-cable drum jack, i-cable pulling sock, njl.

Ukuba unomdla kwiimveliso zethu, unokukhetha ukushiya ulwazi lwakho apha, kwaye siya kuqhagamshelana nawe kungekudala.