Yakagadzirwa ne epoxy resin uye yemhando yepamusoro fiber girazi, ine yakanaka insulation performance, inoshandiswa muindasitiri yemagetsi yekugovera magetsi kuchengetedza vashandi vemagetsi kubva kumagetsi. Zvichienderana nechishandiso chakanamirwa kumagumo etsvimbo inopisa, zvinokwanisika kuyedza magetsi, kuomesa nzungu nemabhaudhi, kuisa waya, kuvhura uye kuvhara switch, kutsiva fuse, kuisa insulating maoko pawaya, uye kuita mamwe mabasa akasiyana. kusaisa vashandi panjodzi huru yekuvhunduka kwemagetsi. Yakakwira Voltage Telescoping Triangle Hot Stick yakagadzirirwa kusvika kureba, kumhanya, kureruka uye kuchengetedzeka.



PDF DOWNLOAD
Details
Tags
 
Features

 

  • Triangle shape enables each section to “lock in automatically”, no need to search for the button
  • Fluorescent green tip chikamu chinoonekwa zvakanyanya
  • Zvikamu zvinogona kubviswa kana kuwedzerwa kuita kuti kamuti ive kureba kwaunoda.
  • Ergonomic dhizaini inopa opareta iri nani inobata nzvimbo yekudzora zvirinani
  • Zvose zvikamu zvine nzvimbo yakatsetseka inopenya yekuchenesa nguva dzose uye kukwirisa
  • Kuvhura nekuvhara bvisa ma switch
  • Kutsiva fuses pane transformers
  • Kuchekerera makumbo emuti
  • Mhando dzakawanda uye kureba zviripo

 

 

 
Advantage

 

  • Mapango ega ega 30cm anogona kushingirira 100kv/5mm
  • Yakasarudzika dhizaini---Triangle pole chubhu chimiro, danda rega rega rinogona kukurumidza kukwidziridzwa nekumisikidzwa, pasina kushandura danda kugadzirisa.
  • Kuonekwa kwepamusoro---Iyo yekunze yejoint bar ipende yefluorescent, iri nyore kushanda kwehusiku nekuzivikanwa. Dzinde guru rinozadzwa nefuro rinodzivirira moto uye mwando kudzivirira kuunganidzwa kwemhute.
  • Zviri nyore kushandisa---Bhatani idzva rekukiya hombe, rine saizi imwe chete, riri nyore kushandisa kunyangwe nemagirovhosi anodzivirira.
  • Esay kuchengetedza--- Iyo yekunze yemuviri wetsvimbo yakatsetseka isina pores, iri nyore kuchenesa zuva nezuva uye maxing.
  • Multi-function-- Iyo yakagadziridzwa yakakwira simba aluminium alloy universal joint inogona kubatanidza zvakasiana misoro yezvishandiso.
  • Zvakawanda zvakatemwa---Kureba kwekuwedzera ndeye 2.43-12m, uye kureba kwechibvumirano i1.485-1.82m.
Read More About telescoping hot stick
  •  
 
Tsanangudzo

 

 

Model

Hurefu hwakawedzerwa(m)

Urefu hwakadzokororwa(m)

Base dhayamita(mm)

Zvikamu

Huremu(kg)

THS-12

3.8(12’7’’)

1.485

37(1.45’’)

3

1.85

THS-16

5(16’9’’)

1.55

40.4(1.61’’)

4

2.6

THS-20

6.43(21’)

1.625

44.6(1.75’’)

5

3.4

THS-25

7.8(25’6’’)

1.67

48.4(1.91’’)

6

4.25

THS-30

9.21(30’)

1.72

52.4(2.07’’)

7

5.1

THS-35

10.6(35’)

1.77

56.5(2.22’’)

8

6.2

THS-40

12(39’6’’)

1.82

60.3(2.38’’)

9

7.2

 

Using High Voltage Telescoping Triangle Hot Stick in Overhead Line Repair


Using High Voltage Telescoping Triangle Hot Stick in Overhead Line Repair is an essential practice for maintaining the safety and efficiency of electrical power systems. The High Voltage Telescoping Triangle Hot Stick is specifically designed for working with energized overhead power lines, allowing technicians to perform repairs without shutting down the system. Its telescopic design enables workers to reach high or difficult-to-access lines while maintaining a safe distance from live electrical currents, reducing the risk of accidents and improving operational efficiency.


One of the primary benefits of using a High Voltage Telescoping Triangle Hot Stick in overhead line repair is enhanced safety. The triangular configuration provides additional stability and strength, allowing for precise handling of tools and equipment during maintenance tasks. Technicians can safely manipulate connectors, insulators, and other line components while standing on the ground or from a bucket truck, minimizing exposure to high-voltage hazards.


In addition to safety, the High Voltage Telescoping Triangle Hot Stick offers versatility and convenience. Its extendable sections make it easy to adjust length according to the height and reach required for different overhead lines. This flexibility ensures that repair tasks, from routine maintenance to emergency interventions, can be performed quickly and effectively, reducing downtime for power distribution systems.


Furthermore, using a High Voltage Telescoping Triangle Hot Stick improves productivity by enabling multiple types of overhead line repairs with a single tool. From tightening fittings to replacing damaged insulators, the stick allows technicians to complete their work efficiently while maintaining strict safety standards. Its durable construction ensures long-lasting performance, even under harsh outdoor conditions.


In conclusion, using a High Voltage Telescoping Triangle Hot Stick in overhead line repair is a critical practice for modern electrical maintenance. It combines safety, efficiency, and reliability, making it an indispensable tool for power utility technicians and line maintenance professionals.

 

High Voltage Telescoping Triangle Hot Stick Applications in Substations


High Voltage Telescoping Triangle Hot Stick Applications in Substations play a crucial role in ensuring safe and efficient electrical operations. Substations contain high-voltage equipment such as transformers, circuit breakers, and disconnect switches that require routine maintenance and occasional emergency interventions. The High Voltage Telescoping Triangle Hot Stick is specifically designed to allow technicians to handle these tasks safely while minimizing exposure to live electrical currents.


One of the main applications of a High Voltage Telescoping Triangle Hot Stick in substations is performing maintenance on energized equipment. Technicians can operate switches, tighten connections, and replace insulators without shutting down the system, maintaining uninterrupted power supply to critical infrastructure. The telescopic feature allows the stick to extend to varying heights, making it ideal for reaching overhead components or high-mounted equipment within the substation.


The triangular design of the hot stick provides enhanced stability and strength, ensuring precise control when handling tools or operating equipment. This stability reduces the risk of accidental slips or contact with high-voltage surfaces, improving overall workplace safety. Additionally, the durable materials used in construction ensure the hot stick can withstand harsh outdoor conditions commonly found in substation environments, including extreme temperatures, wind, and rain.


Another key benefit is versatility. The High Voltage Telescoping Triangle Hot Stick can be used for multiple substation tasks, from routine inspections and preventive maintenance to urgent repairs. Its portability and lightweight design allow technicians to maneuver it easily within tight substation layouts, improving operational efficiency while adhering to strict safety protocols.


In summary, High Voltage Telescoping Triangle Hot Stick applications in substations are essential for modern power system management. They provide a safe, reliable, and efficient solution for handling energized equipment, ensuring uninterrupted service, reducing downtime, and protecting maintenance personnel from high-voltage hazards."

 

High Voltage Telescoping Triangle Hot Stick for Energized Equipment Operations


High Voltage Telescoping Triangle Hot Stick for Energized Equipment Operations is a vital tool for electricians and maintenance technicians working with live electrical systems. Performing tasks on energized equipment requires strict safety measures, and the High Voltage Telescoping Triangle Hot Stick provides both safety and efficiency in these high-risk environments. Its design allows technicians to work on high-voltage components without directly contacting live circuits, minimizing the risk of electrical accidents.


One of the primary advantages of using a High Voltage Telescoping Triangle Hot Stick for energized equipment operations is its extendable functionality. The telescoping sections allow the user to adjust the length according to the height of the equipment or the distance needed to maintain a safe working perimeter. This feature is especially important when operating on transformers, circuit breakers, and switchgear in substations or industrial facilities.


The triangular design of the hot stick adds stability and strength, which is essential when performing precise tasks on energized equipment. Whether tightening fittings, replacing insulators, or operating high-voltage switches, the High Voltage Telescoping Triangle Hot Stick ensures that technicians can complete their work safely and accurately. Its lightweight yet durable construction makes it easy to maneuver while withstanding the demands of outdoor and industrial environments.


In addition to safety and stability, this hot stick enhances operational efficiency. Technicians can perform multiple tasks without needing to shut down equipment, reducing downtime and maintaining continuous power supply. The ergonomic design also minimizes fatigue during prolonged operations, allowing for more effective and consistent maintenance performance.


In conclusion, the High Voltage Telescoping Triangle Hot Stick for energized equipment operations is an indispensable tool in modern electrical maintenance. It combines safety, precision, and efficiency, enabling technicians to work confidently on live systems while protecting both personnel and equipment from high-voltage hazards.

 

Kana iwe uchifarira zvigadzirwa zvedu, unogona kusarudza kusiya ruzivo rwako pano, uye isu tichabatana newe munguva pfupi.


logo
BlLo lmport & Éxport inyanzvi musimba uye tambo midziyo uye maturusi ekugadzirisa,Qur main producis iFRP duct rodder, cable rollerscable pulling winch, tambo chigubhu jack, tambo yekudhonza sock, nezvimwe.

Kana iwe uchifarira zvigadzirwa zvedu, unogona kusarudza kusiya ruzivo rwako pano, uye isu tichabatana newe munguva pfupi.